HPLC Guard Columns and Cartridges
- (30)
- (1)
- (30)
- (14)
- (1)
- (4)
- (162)
- (1)
- (6)
- (120)
- (3)
- (1)
- (53)
- (3)
- (3)
- (1)
- (11)
- (17)
- (23)
- (13)
- (2)
- (22)
- (3)
- (80)
- (1)
- (13)
- (3)
- (2)
- (30)
- (3)
- (22)
- (9)
- (2)
- (24)
- (3)
- (1)
- (2)
- (55)
- (2)
- (69)
- (5)
- (5)
- (5)
- (6)
- (329)
- (3)
- (2)
- (6)
- (1)
- (7)
- (3)
- (3)
- (3)
- (15)
- (4)
- (1)
- (22)
- (2)
- (148)
- (5)
- (1)
- (4)
- (2)
- (72)
- (1)
- (14)
- (129)
- (4)
- (94)
- (11)
- (1)
- (8)
- (2)
- (2)
- (74)
- (18)
- (4)
- (3)
- (2)
- (23)
- (11)
- (10)
- (2)
- (4)
- (1)
- (36)
- (9)
- (2)
- (5)
- (3)
- (1)
- (1)
- (1)
- (3)
- (6)
- (1)
- (42)
- (2)
- (3)
- (45)
- (3)
- (5)
Filtered Search Results
YMC America, Inc TMS 3UM 120A 20X4MM PK/5
TM12S03-0204GC: TMS, 3um, 120A, 20X4mm Cartridge, pk/5
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
YMC America, Inc OCTYL 5UM 200A 20X4MM PK/5
OC20S05-0204GC: Octyl, 5um, 200A, 20X4mm Cartridge, pk/5
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Mac-Mod Avantor ACE AQ, 100 Å, 3 µm, 1.0 x 10 mm Guard Cartridges (5/pk)
Avantor ACE Excel UHPLC and HPLC columns are manufactured with 100 Å Ultra-Inert Base Deactivated Silica specifically designed for your HPLC method development needs - Note SuperC18 is 95 Å Avantor ACE HPLC columns are available in a wide range of bonded phases (i.e. C18, C18-AR, C18-PFP, C18-Amide, CN-ES, SuperC18, NH2, C8, C4, Phenyl, AQ, CN and Sil). Avantor ACE Excel UHPLC and HPLC columns are avaialble in 1.7, 2, 3, and 5 µm particle sizes in all analytical column sizes. All Avantor ACE Excel columns are known for their excellent peak shape and batch to batch reproducibility. Columns are packed in 1000 bar UHPLC hardware. Note: Avantor ACE Excel UHPLC guard columns are available for all 1.7 and 2 µm particle sizes across all 2.1 mm - 4.6 mm column ID - Note: H0011 connects directly to the analytical column - Guard column cartridges are available in 3-packs. For 3 and 5 µm Excel columns use same guard systems used for Avantor ACE HPLC analytical columns.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Mac-Mod Avantor ACE C18-HL, 90 Å, 5 µm, 3.0/4.6 x 10 mm Guard Cartridges (5/pk)
Avantor ACE Excel UHPLC and HPLC columns are manufactured with 100 Å Ultra-Inert Base Deactivated Silica specifically designed for your HPLC method development needs - Note SuperC18 is 95 Å Avantor ACE HPLC columns are available in a wide range of bonded phases (i.e. C18, C18-AR, C18-PFP, C18-Amide, CN-ES, SuperC18, NH2, C8, C4, Phenyl, AQ, CN and Sil). Avantor ACE Excel UHPLC and HPLC columns are avaialble in 1.7, 2, 3, and 5 µm particle sizes in all analytical column sizes. All Avantor ACE Excel columns are known for their excellent peak shape and batch to batch reproducibility. Columns are packed in 1000 bar UHPLC hardware. Note: Avantor ACE Excel UHPLC guard columns are available for all 1.7 and 2 µm particle sizes across all 2.1 mm - 4.6 mm column ID - Note: H0011 connects directly to the analytical column - Guard column cartridges are available in 3-packs. For 3 and 5 µm Excel columns use same guard systems used for Avantor ACE HPLC analytical columns.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Mac-Mod Avantor Allsep Anion IC, 5 µm, 3.0/4.6 x Guard Cartridges (3/pk)
Avantor Allsep Anion HPLC columns are a methacrylate based phase with quaternary ammonium functional groups, optimized for use with both suppressed and non-suppressed conductivity detection. Avantor Allsep Anion HPLC columns are compatible with common IC mobile phases, such as carbonate, bicarbonate, p-hydroxybenzoic acid, phthalic acid, succinic acid and sodium octane sulfonate. Avantor Allsep Anion HPLC columns are recommended for applications involving inorganic anions, weak and strong acid ions, metal complexes and organic acids. These columns meet the requirements for the EPA method 300.0 Part A for determining inorganic ions in water. Avantor Allsep Anion HPLC columns are 7 µm polymer based anion exchange phase used with suppressed or non-suppressed conductivity detection. Avantor Allsep Anion HPLC columns has a pH range of 2 - 10. Avantor Allsep Anion HPLC columns can be used with 0 - 100% organic modifier.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Mac-Mod Avantor ACE Excel C18, 100 Å, 4.6 x 5 mm UHPLC Guard Cartridges (3/pk)
Avantor ACE Excel UHPLC and HPLC columns are manufactured with 100 Å Ultra-Inert Base Deactivated Silica specifically designed for your HPLC method development needs - Note SuperC18 is 95 Å Avantor ACE HPLC columns are available in a wide range of bonded phases (i.e. C18, C18-AR, C18-PFP, C18-Amide, CN-ES, SuperC18, NH2, C8, C4, Phenyl, AQ, CN and Sil). Avantor ACE Excel UHPLC and HPLC columns are avaialble in 1.7, 2, 3, and 5 µm particle sizes in all analytical column sizes. All Avantor ACE Excel columns are known for their excellent peak shape and batch to batch reproducibility. Columns are packed in 1000 bar UHPLC hardware. Note: Avantor ACE Excel UHPLC guard columns are available for all 1.7 and 2 µm particle sizes across all 2.1 mm - 4.6 mm column ID - Note: H0011 connects directly to the analytical column - Guard column cartridges are available in 3-packs. For 3 and 5 µm Excel columns use same guard systems used for Avantor ACE HPLC analytical columns.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Mac-Mod Avantor ACE HILIC-N, 100 Å, 3 µm, 3.0/4.6 x 10 mm Guard Cartridges (5/pk)
Avantor ACE HILIC UHPLC and HPLC columns are manufactured with 100 Å Ultra-Inert Base Deactivated Silica specifically designed for your HILIC method development needs. Avantor ACE HILIC UHPLC and HPLC columns are available in 3 different bonded phases HILIC-A (acidic phase), HILIC-B (basic phase), and HILIC-N (neutral phase). Avantor ACE HILIC UHPLC and HPLC columns are available in 1.7, 3, and 5 um particle sizes in all analytical column sizes. All Avantor ACE HILIC columns are known for their excellent peak shape and batch to batch reproducibility. Columns are packed in 1000 bar UHPLC hardware.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Mac-Mod Avantor ACE CN, 100 Å, 5 µm, 3.0/4.6 x 10 mm Guard Cartridges (5/pk)
Avantor ACE Excel UHPLC and HPLC columns are manufactured with 100 Å Ultra-Inert Base Deactivated Silica specifically designed for your HPLC method development needs - Note SuperC18 is 95 Å Avantor ACE HPLC columns are available in a wide range of bonded phases (i.e. C18, C18-AR, C18-PFP, C18-Amide, CN-ES, SuperC18, NH2, C8, C4, Phenyl, AQ, CN and Sil). Avantor ACE Excel UHPLC and HPLC columns are avaialble in 1.7, 2, 3, and 5 µm particle sizes in all analytical column sizes. All Avantor ACE Excel columns are known for their excellent peak shape and batch to batch reproducibility. Columns are packed in 1000 bar UHPLC hardware. Note: Avantor ACE Excel UHPLC guard columns are available for all 1.7 and 2 µm particle sizes across all 2.1 mm - 4.6 mm column ID - Note: H0011 connects directly to the analytical column - Guard column cartridges are available in 3-packs. For 3 and 5 µm Excel columns use same guard systems used for Avantor ACE HPLC analytical columns.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Mac-Mod Avantor ACE C4, 100 Å, 3 µm, 2.1 x 10 mm Guard Cartridges (5/pk)
Avantor ACE Excel UHPLC and HPLC columns are manufactured with 100 Å Ultra-Inert Base Deactivated Silica specifically designed for your HPLC method development needs - Note SuperC18 is 95 Å Avantor ACE HPLC columns are available in a wide range of bonded phases (i.e. C18, C18-AR, C18-PFP, C18-Amide, CN-ES, SuperC18, NH2, C8, C4, Phenyl, AQ, CN and Sil). Avantor ACE Excel UHPLC and HPLC columns are avaialble in 1.7, 2, 3, and 5 µm particle sizes in all analytical column sizes. All Avantor ACE Excel columns are known for their excellent peak shape and batch to batch reproducibility. Columns are packed in 1000 bar UHPLC hardware. Note: Avantor ACE Excel UHPLC guard columns are available for all 1.7 and 2 µm particle sizes across all 2.1 mm - 4.6 mm column ID - Note: H0011 connects directly to the analytical column - Guard column cartridges are available in 3-packs. For 3 and 5 µm Excel columns use same guard systems used for Avantor ACE HPLC analytical columns.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp SunFire C18 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk;
SunFire C18 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk;
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp Waters Guard Column, SEC, 125Å, 2.5 μm, 4.6 mm X 30 mm
This guard column utilizes 2.5 μm Ethylene Bridged Hybrid (BEH) particles with a diol-bonded surface, designed for separating proteins from 1,000 to 80,000 Daltons.
- Particle size: 2.5 μm
- Pore size: 125 Å
- Dimensions: 4.6 mm X 30 mm
- Chemistry: SEC
- Separation mode: Gel Filtration (aqueous)
- Particle substrate: Hybrid
- pH range: 2.5 to 8 pH
- Temperature limits: 60 °C
- Maximum pressure: 5500 psi (379 Bar)
- Bonding technology: Diol (OH)
- Silanol activity: Low
- Molecular weight range: 1,000 to 80,000 Daltons
- Particle shape: Spherical
- Endfitting type: Parker-style
- QC tested: Protein
- Packing solvent: 20% methanol in water
- Surface area: 220
- System: UHPLC, UPLC, HPLC
- USP classification: L20, L33, L59
- Carbon load: 12 %
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp Waters Guard Column, 200 Å, 2.5 μm, 4.6 x 30 mm
Waters Guard Column, 200 Å, 2.5 μm, 4.6 x 30 mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp BioResolve SCX mAb Column, 3 μm, 2.1 mm x 100 mm
The BioResolve SCX mAb Column with VanGuard FIT is a corrosion-resistant column featuring non-porous, polymer-based particles with optimized sulfonic acid ligands. It delivers reproducible, high-resolution, charge-based separations of monoclonal antibodies (mAbs) and other proteins in LC and LC-MS applications. With VanGuard FIT, it maximizes column life, and each batch is QC tested for consistent performance. It is designed for charge variant analysis of monoclonal antibodies.
- Corrosion-resistant design.
- Non-porous, polymer-based particles with optimized ligands.
- Reproducible, high-resolution separations for mAbs and proteins.
- Compatible with LC and LC-MS.
- VanGuard FIT for extended column life and maintained resolution.
- Batch QC tested for consistent performance.
- Designed for charge variant analysis of monoclonal antibodies.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp WATERS CORPORATION Guard Cartridge, CSH C18, 1.7 μm, 2.1 x 5 mm
These integrated guard cartridges are designed to work with VanGuard FIT columns. They protect the analytical column from matrix and sample contaminants, thereby extending the column’s lifetime.
- Fully integrated guard cartridges
- Protects analytical columns from matrix and sample contaminants
- Extends column lifetime
- System: UPLC
- Technique: LC
- Particle size: 1.7 μm
- Column dimensions: 2.1 mm inner diameter, 5 mm length
- Chemistry: C18
- Separation mode: Reversed phase
- pH range: 1 to 11
- Maximum pressure: 18000 psi (1240 Bar)
- Units per package: 3
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp ACQUITY UPLC VanGuard FIT Cartridge, 1.7 μm, 2.1 mm ID, 5 mm
ACQUITY Premier cartridges are designed to work with ACQUITY Premier VanGuard FIT columns. These cartridges provide fully integrated guard protection for the analytical column, shielding it from matrix and sample contaminants, which helps to extend the column's lifetime.
- Works with VanGuard FIT columns
- Fully integrated guard cartridges
- Protects the analytical column from matrix and sample contaminants
- Extends column lifetime
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More